Yavuzsan Automotive

ASSEMBLY FAULT 2

277

APPEARANCE

  • Hub contact surface separated or deteriorated

REASONS

  • Non-compliance with the tightening torque and sequence recommended by the manufacturer during the tightening process

EFFECTS

  • Separation at the disc contact surface. Complete failure of the brake system

SOLUTION

  • Fully check the brake system and related parts. Replace all failed components and install new discs following the manufacturer's recommended tightening torque and sequence during tightening.